See and compare accurate results from pulmonary function tests in seconds with the Welch Allyn PC-Based SpiroPerfect Spirometer. Clearly evaluate pulmonary obstruction or restriction, increase success rates of patients who are undergoing smoking cessation, show progress, and help pediatric patients comply with test procedures. This powerful and accurate Windows-based software solution interfaces with EMR or patient management systems for onsite or offsite review of key data. Part of the CardioPerfect Workstation suite.
What's Included:
- SpiroPerfect Spirometry Module
- 3 -Liter Calibration Syring (Optional - Included with #SPIRO-S)
- SpiroPerfect Sensor
- Pressure Tubing
- 8 Flow Transducers
- 2 Training Posters
- CardioPerfect Workstation Software
SpiroPerfect
|
Computer-based full diagnostic spirometer
|
Test
|
FVC, SVC, MVV, Pre- and Post-BD
|
Sensor Type
|
Pneumotach
|
Power Equipment
|
None, obtained from USB port
|
Accuracy
|
Meets or exceeds 1944 ATS standard
|
Reproducibility
|
Meets or exceeds 1994 ATS standard
|
Volume Range
|
0-14 L
|
Flow Range
|
+-14 L/sec
|
Software
|
Windows XP, Vista and 7 compatible
|
Predictive Norms
|
Berglund 1963, Crapo 1981, Dockery 1983, ECCS/Quanjer 1993, Falaschetti 2004, Forche II 1988, Langhammer 2001, Hedenstrom 1986, Hibbert 1989, Hsu 1979, Knudson 1976, Knudson 1983, Koillinen 1998, Kory 1961, Morris 1971, NHANES III 1999, Polgar 1971, Roca 1986, Schoenberg 1978, Solymar 1980, Viljanen 1981, Wang 1993, Zapletal 1969
|
Interpretation
|
1991 ATS Interpretation Standards. Automatic can be disabled. Manual interpretation available. Lung age calculation
|
Reports
|
Multiple report templates including FVC, SVC, MVV, measurement, and trend
|
Incentive Graphic
|
Fireman
|
Parameters
|
FVC, FFEv0.5, FFEV1, FFEV2, FFEV3, FFEV5, FFEV6, FFEV0.5, FFEV0.5%, FFEV1%, FFEV1/FVC, FFEV2%, FFEV3%, FFEV5%, FFEV6%, PEF, FEF25, FEF50, FEF75, FEF0.2-1.2, FEF25-75, FEF75-85, FEF50/FIF50, FEV1/FEV6, FET, MEF25, MEF50, MEF75, FIVC, FIV1, FIV1%, PIF, FIF50
SVC, ERV, IRV, VT, IC, BF, MV, Tin, Tex, Tin/Tex
MVV, MV, VT, BF, DFRC
|
Bidirectional
|
Allscripts MyWay, Allscripts Pro, Allscripts Enterprise
|
Connectivity
|
eClinicalWorks, e-MDs, GE Centricity, GEMMS, Greenway, Pactice Partners, NextGen
|
Quality Checks
|
Effort acceptability and test reproducibility checks Audio and visual incetive for assistance in coaching patients
|
Connectivity
|
Part of the CardioPerfect Diagnostic Suite Export compatible with most electronic medical records programs
|
Minimum Computer Requirements (recommended)
|
Processor: Intel Pentium III (Pentium IV or higher) Hard Drive: 2 GB (4 GB or more) RAM: 256 MB (512 MB or higher) Monitor Resolution: 1024 x 768 true color Operating Systems: Windows XP, VIsta and 7 CD-ROM: Required for instillation Printers: Color printer recommended. Compatible with inkjet and laser printers. Laser printers require a minimum of 2 MB of memory
|
Performance Standards
|
SpiroPerfect meets of exceeds the following standards: ATS/ERS - American Thoracic Society/European Respiratory Society, Standardization of Spirometry, 2005 Update NIOSH - National Institute for Occupational Safety and Health OSHA - Occupational Safety and Health Administration SSD - Social Security Disability ECCS - European Community for Coal and Steel
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|